GHPV is one of the largest PV suppliers in China, ranked in the TOP 3 in the industry.
GHPV is one of the largest PV suppliers in China, ranked in the TOP 3 in the industry.
MAX MODULE EFFICIENCY : 23.0%
POWER TOLERANCE : 0~3%
FIRST YEAR POWER DEGRADATION : <1.5%
Suitable for distributed projects
Excellent outdoor power generation performance
High module quality ensures long-term reliability
Max Module Efficiency
Power Tolerance
First Year Power Degradation
Year 2-25 Power Degradation
25-year Warranty for Materials and Processing | 25-year Warranty for Extra Linear Power Output |
Mechanical Parameters | |
Cell Orientation | 108 (6×18) |
Junction Box | IP68, three diodes |
Output Cable | 4mm², ±1200mm, length can be customized |
Glass | Single glass, 3.2mm coated tempered glass |
Frame | Anodized aluminum alloy frame |
Weight | 20.8kg |
Dimension | 1722×1134×30mm |
Packaging | 36pcs per pallet / 216pcs per 20' GP / 936pcs per 40' HC |
Electrical Characteristics | ||||||||
Module Type | LR5-54HTH-435M | LR5-54HTH-440M | LR5-54HTH-445M | LR5-54HTH-450M | ||||
Testing Condition | STC | NOCT | STC | NOCT | STC | NOCT | STC | NOCT |
Maximum Power (Pmax/W) | 435 | 325 | 440 | 329 | 445 | 332 | 450 | 336 |
Open Circuit Voltage (Voc/V) | 39.33 | 36.93 | 39.53 | 37.11 | 39.73 | 37.30 | 39.93 | 37.49 |
Short Circuit Current (Isc/A) | 14.22 | 11.49 | 14.30 | 11.55 | 14.37 | 11.61 | 14.45 | 11.67 |
Voltage at Maximum Power (Vmp/V) | 33.04 | 30.15 | 33.24 | 30.33 | 33.44 | 30.51 | 33.64 | 30.70 |
Current at Maximum Power (Imp/A) | 13.17 | 10.78 | 13.24 | 10.85 | 13.31 | 10.90 | 13.38 | 10.95 |
Module Efficiency (%) | 22.3 | 22.5 | 22.8 | 23.0 |
STC: AM1.5 1000W/m² 25℃
NOCT: AM1.5 800W/m² 20℃ 1m/s
Test uncertainty for Pmax: ±3%
Operating Parameters | |
Operational Temperature | -40℃ ~ +85℃ |
Power Output Tolerance | 0~3% |
Voc and Isc Tolerance | ±3% |
Maximum System Voltage | DC1500V (IEC/UL) |
Maximum Series Fuse Rating | 25A |
Nominal Operating Cell Temperature | 45±2℃ |
Protection Class | Class II |
Fire Rating | UL type 1 or 2, IEC Class C |
Mechanical Loading
Front Side Maximum Static Loading | 5400Pa |
Rear Side Maximum Static Loading | 2400Pa |
Hailstone Test | 25mm Hailstone at the speed of 23m/s |
Temperature Ratings (STC)
Temperature Coefficient of Isc | +0.050% / ℃ |
Temperature Coefficient of Voc | -0.230% / ℃ |
Temperature Coefficient of Pmax | -0.290% / ℃ |
Mainly distributed in countries and regions:Germany, Spain, Italy, Tunisia, France, Netherlands, United Kingdom, Austria, Switzerland, Czech Republic, Sweden, Australia, New ZealandSouth Africa, United Arab Emirates, Argentina, Brazil, Colombia, Canada, Malaysia, Singapore, Thailand, Vietnam, Japan
Faq