GHPV is one of the largest PV suppliers in China, ranked in the TOP 3 in the industry.
GHPV is one of the largest PV suppliers in China, ranked in the TOP 3 in the industry.
MAX MODULE EFFICIENCY : 22.0%
POWER TOLERANCE : 0~3%
FIRST YEAR POWER DEGRADATION : <1.5%
Suitable for distributed projects
Excellent outdoor power generation performance
High module quality ensures long-term reliability
Max Module Efficiency
Power Tolerance
First Year Power Degradation
Year 2-25 Power Degradation
15-year Warranty for Materials and Processing | 25-year Warranty for Extra Linear Power Output |
Mechanical Parameters | |
Cell Orientation | 108 (6×18) |
Junction Box | IP68, three diodes |
Output Cable | 4mm², ±1200mm, length can be customized |
Glass | Single glass, 3.2mm coated tempered glass |
Frame | Anodized aluminum alloy frame |
Weight | 20.8kg |
Dimension | 1722×1134×30mm |
Packaging | 36pcs per pallet / 216pcs per 20' GP / 936pcs per 40' HC |
Electrical Characteristics | ||||||||
Module Type | LR5-54HTH-415M | LR5-54HTH-420M | LR5-54HTH-425M | LR5-54HTH-430M | ||||
Testing Condition | STC | NOCT | STC | NOCT | STC | NOCT | STC | NOCT |
Maximum Power (Pmax/W) | 415 | 310 | 420 | 314 | 425 | 318 | 430 | 321 |
Open Circuit Voltage (Voc/V) | 38.53 | 36.18 | 38.73 | 36.36 | 38.93 | 36.55 | 39.13 | 36.74 |
Short Circuit Current (Isc/A) | 13.92 | 11.24 | 14.00 | 11.31 | 14.07 | 11.36 | 14.15 | 11.43 |
Voltage at Maximum Power (Vmp/V) | 32.24 | 29.42 | 32.44 | 29.60 | 32.64 | 29.78 | 32.84 | 29.97 |
Current at Maximum Power (Imp/A) | 12.88 | 10.54 | 12.95 | 10.60 | 13.03 | 10.67 | 13.10 | 10.72 |
Module Efficiency (%) | 21.3 | 21.5 | 21.8 | 22.0 |
STC: AM1.5 1000W/m² 25℃
NOCT: AM1.5 800W/m² 20℃ 1m/s
Test uncertainty for Pmax: ±3%
Operating Parameters | |
Operational Temperature | -40℃ ~ +85℃ |
Power Output Tolerance | 0~3% |
Voc and Isc Tolerance | ±3% |
Maximum System Voltage | DC1500V (IEC/UL) |
Maximum Series Fuse Rating | 25A |
Nominal Operating Cell Temperature | 45±2℃ |
Protection Class | Class II |
Fire Rating | UL type 1 or 2, IEC Class C |
Mechanical Loading
Front Side Maximum Static Loading | 5400Pa |
Rear Side Maximum Static Loading | 2400Pa |
Hailstone Test | 25mm Hailstone at the speed of 23m/s |
Temperature Ratings (STC)
Temperature Coefficient of Isc | +0.050% / ℃ |
Temperature Coefficient of Voc | -0.230% / ℃ |
Temperature Coefficient of Pmax | -0.290% / ℃ |
Mainly distributed in countries and regions:Germany, Spain, Italy, Tunisia, France, Netherlands, United Kingdom, Austria, Switzerland, Czech Republic, Sweden, Australia, New ZealandSouth Africa, United Arab Emirates, Argentina, Brazil, Colombia, Canada, Malaysia, Singapore, Thailand, Vietnam, Japan