GHPV is one of the largest PV suppliers in China, ranked in the TOP 3 in the industry.
GHPV is one of the largest PV suppliers in China, ranked in the TOP 3 in the industry.
MAX MODULE EFFICIENCY : 23.9%
POWER TOLERANCE : 0~3%
FIRST YEAR POWER DEGRADATION :<1%
Suitable for Distribution Market
Highest efficiency with the best energy generation performance
TaiRay wafer& BC technologyenhances high product reliability
More suitable for industrial and commercia cement roofs and high temperature scenarios
Max Module Efficiency
Power Tolerance
First Year Power Degradation
Year 2-30 Power Degradation
![]() | 12-year Warranty for Materials and Processing | ![]() | 30-year Warranty for Extra Linear Power Output |
Mechanical Parameters | |
Cell Orientation | 144 (6×24) |
Junction Box | IP68, three diodes |
Output Cable | 4mm², +400, -200mm/±1400mm, length can be customized |
Glass | Dual glass, 2.0+2.0mm semi-tempered glass |
Frame | Anodized aluminum alloy frame |
Weight | 33.5kg |
Dimension | 2382x1134x30mm |
Packaging | 36pcs per pallet/144pcs per 20’GP/720pcs per 40'HC |
Electrical Characteristics | ||||||||||
Module Type | LR7-72HVD-625M | LR7-72HVD-630M | LR7-72HVD-635M | LR7-72HVD-640M | LR7-72HVD-645M | |||||
Testing Condition | STC | NOCT | STC | NOCT | STC | NOCT | STC | NOCT | STC | NOCT |
Maximum Power (Pmax/W) | 625 | 475.8 | 630 | 479.6 | 635 | 483.4 | 640 | 487.2 | 645 | 491.0 |
Open Circuit Voltage (Voc/V) | 53.30 | 50.65 | 53.40 | 50.75 | 53.50 | 50.84 | 53.60 | 50.94 | 53.70 | 51.03 |
Short Circuit Current (Isc/A) | 14.85 | 11.93 | 14.93 | 12.00 | 15.01 | 12.06 | 15.09 | 12.12 | 15.17 | 12.18 |
Voltage at Maximum Power (Vmp/V) | 44.16 | 41.97 | 44.26 | 42.06 | 44.36 | 42.16 | 44.46 | 42.25 | 44.56 | 42.35 |
Current at Maximum Power (Imp/A) | 14.16 | 11.35 | 14.24 | 11.42 | 14.32 | 11.48 | 14.40 | 11.54 | 14.48 | 11.61 |
Module Efficiency (%) | 23.1 | 23.3 | 23.5 | 23.7 | 23.9 |
Operating Parameters | |
Operational Temperature | -40°C~+85°C |
Power Output Tolerance | 0~3% |
Maximum System Voltage | DC1500V (IEC/UL) |
Maximum Series Fuse Rating | 30A |
Nominal Operating Cell Temperature | 45±2℃ |
Protection Class | Class II |
Fire Rating | UL type 29 lEC Class C |
Mechanical Loading
Front Side Maximum Static Loading | 5400Pa |
Rear Side Maximum Static Loading | 2400Pa |
Hailstone Test | 25mm Hailstone at the speed of 23m/s |
Temperature Ratings (STC)
Temperature Coefficient of Isc | +0.050% / ℃ |
Temperature Coefficient of Voc | -0.200% / ℃ |
Temperature Coefficient of Pmax | -0.260% / ℃ |
Mainly distributed in countries and regions:Germany, Spain, Italy, Tunisia, France, Netherlands, United Kingdom, Austria, Switzerland, Czech Republic, Sweden, Australia, New ZealandSouth Africa, United Arab Emirates, Argentina, Brazil, Colombia, Canada, Malaysia, Singapore, Thailand, Vietnam, Japan