GHPV is one of the largest PV suppliers in China, ranked in the TOP 3 in the industry.
GHPV is one of the largest PV suppliers in China, ranked in the TOP 3 in the industry.
MAX MODULE EFFICIENCY : 22.6%
POWER TOLERANCE : 0~3%
FIRST YEAR POWER DEGRADATION : <1.5%
Simple design embodies modern style
High-quality module guarantees long-term reliability
Max Module Efficiency
Power Tolerance
First Year Power Degradation
Year 2-25 Power Degradation
12-year Warranty for Materials and Processing | 25-year Warranty for Extra Linear Power Output |
Mechanical Parameters | |
Cell Orientation | 144 (6x24) |
Junction Box | IP68 |
Output Cable | 4mm², +400, -200mm/±1400mm, length can be customized |
Glass | Dual glass, 2.0mm semi-tempered glass |
Frame | Anodized aluminum alloy frame |
Weight | 31.8kg |
Dimension | 2278x1134x30mm |
Packaging | 36pcs per pallet/180pcs per 20'GP/720pcs per 40’HC |
Electrical Characteristics | ||||||||||||
Module Type | LR5-72HTD-560M | LR5-72HTD-565M | LR5-72HTD-570M | LR5-72HTD-575M | LR5-72HTD-580M | LR5-72HTD-585M | ||||||
Testing Condition | STC | NOCT | STC | NOCT | STC | NOCT | STC | NOCT | STC | NOCT | STC | NOCT |
Maximum Power (Pmax/W) | 560 | 418 | 565 | 422 | 570 | 426 | 575 | 430 | 580 | 433 | 585 | 437 |
Open Circuit Voltage (Voc/V) | 51.70 | 48.54 | 51.85 | 48.68 | 52.00 | 48.82 | 52.15 | 48.96 | 52.30 | 49.10 | 52.45 | 49.25 |
Short Circuit Current (Isc/A) | 13.87 | 11.20 | 13.93 | 11.25 | 14.00 | 11.31 | 14.06 | 11.36 | 14.13 | 11.41 | 14.19 | 11.46 |
Voltage at Maximum Power (Vmp/V) | 43.25 | 39.47 | 43.40 | 39.60 | 43.55 | 39.74 | 43.70 | 39.88 | 43.85 | 40.01 | 44.00 | 40.15 |
Current at Maximum Power (Imp/A) | 12.95 | 10.60 | 13.02 | 10.66 | 13.09 | 10.72 | 13.16 | 10.77 | 13.23 | 10.83 | 13.30 | 10.89 |
Module Efficiency (%) | 21.7 | 21.9 | 22.1 | 22.3 | 22.5 | 22.6 |
STC: AM1.5 1000W/m² 25℃
NOCT: AM1.5 800W/m² 20℃ 1m/s
Test uncertainty for Pmax: ±3%
Operating Parameters | |
Operational Temperature | -40℃ ~ +85℃ |
Power Output Tolerance | 0~3% |
Voc and Isc Tolerance | ±3% |
Maximum System Voltage | DC1500V (IEC/UL) |
Maximum Series Fuse Rating | 30A |
Nominal Operating Cell Temperature | 45±2℃ |
Protection Class | Class II |
Fire Rating | IEC Class C |
Mechanical Loading
Front Side Maximum Static Loading | 5400Pa |
Rear Side Maximum Static Loading | 2400Pa |
Hailstone Test | 25mm Hailstone at the speed of 23m/s |
Temperature Ratings (STC)
Temperature Coefficient of Isc | +0.050% / ℃ |
Temperature Coefficient of Voc | -0.230% / ℃ |
Temperature Coefficient of Pmax | -0.280% / ℃ |
Mainly distributed in countries and regions:Germany, Spain, Italy, Tunisia, France, Netherlands, United Kingdom, Austria, Switzerland, Czech Republic, Sweden, Australia, New ZealandSouth Africa, United Arab Emirates, Argentina, Brazil, Colombia, Canada, Malaysia, Singapore, Thailand, Vietnam, Japan
Faq